Mono Screw [100 Units/Box]

PRODUCT INFO

Mono Screw threads are heatless press-cut, dissolvable polydioxanone (PDO) sutures with a smooth (non-barbed) monofilament wound in a coiled screw configuration. They are manufactured from high-purity polydioxanone, a biocompatible material used in surgical sutures for decades. Because the threads are press-cut without heat treatment, they retain their molecular integrity and flexibility, which supports uniform performance during insertion and predictable absorption over time. The coiled configuration increases the surface area of thread in contact with surrounding tissue relative to a straight mono thread.

  • Thread Type: Screw (coiled), non-barbed Smooth PDO
  • Thread Material: Polydioxanone (PDO)

INDICATIONS

Injection with PDO Mono Screw threads is indicated for soft tissue approximation where use of an absorbable suture is appropriate. Mono Screw threads are typically implanted intradermally or subdermally:
  • Soft tissue approximation where use of an absorbable suture is appropriate
  • Dermatological applications on the skin only
  • Intradermal or subdermal placement
  • Absorbable - degrades and dissolves in tissue over time
  • Single-use, by licensed medical professionals trained in PDO thread insertion techniques

PACKAGING & STORAGE

Keep out of reach of children. All threads should be stored in their original, unopened pouches and foil bags, in a temperature-controlled room, away from direct sunlight.
  • The outer resealable foil bag protects the sutures from light and humidity.
  • The inner pouches maintain sterility.
  • Once opened, use within 24 hours.
  • Sterilized by Ethylene Oxide. Non-pyrogenic.
  • Single-use only. Discard immediately after opening. Do not resterilize or reuse.
  • Do not use if packaging is damaged or compromised.
  • Each package includes the lot number, manufacturing date, and expiration date, located on the bottom of the back label.

CONTRAINDICATIONS, WARNINGS & PRECAUTIONS

PDO sutures should not be used in patients with any known allergy or foreign body sensitivity to polydioxanone. They should not be used where internal fixation is contraindicated. Implanting any foreign material into tissue may cause localized reactions. A full review of the patient's medical history must be performed, including allergies, prior treatments, or conditions at the treatment site. Use is contraindicated in the following cases:
  • Pregnancy or breastfeeding
  • Active infection or inflammation at the treatment area
  • Severe allergies or hypersensitivity to surgical sutures
  • Repeated unsuccessful thread treatments
  • Anaphylactic or allergic reaction to injectable products
  • Non-compliance with post-procedure instructions
  • Active acne, cystic acne, or dermatitis at the site
  • Tendency to develop keloids
  • Malignancy or ongoing cancer treatment
  • Autoimmune or connective tissue disorders (e.g., scleroderma, sarcoidosis)
  • Diabetes, tuberculosis, or other chronic systemic diseases
  • Patients on anticoagulants or with bleeding disorders
  • Active viral infections such as Hepatitis B, Hepatitis C, or HIV
  • Recent influenza or other acute infections
  • Presence of permanent implants (e.g., silicone) in the intended treatment area

DISCLAIMER

Mono Screw PDO threads are absorbable surgical sutures indicated for soft tissue approximation and skin revitalization where use of an absorbable suture is appropriate.The product should only be used by licensed medical professionals trained in PDO thread insertion techniques.Results and duration of effect may vary depending on patient condition, lifestyle, and treatment area.

Additional information

Weight 363 g
Dimensions 254 × 178 × 178 mm
Gauge & Length

26G X 50mm, 26G X 60mm, 26G X 90mm, 27G X 40mm, 27G X 50mm, 27G X 60mm, 27G X 90mm, 29G X 40mm, 29G X 50mm, 29G X 60mm

Exchange Policy

This Exchange Policy applies to all products distributed in the United States DBM Aesthetics, whether purchased directly, through an authorized DBM Aesthetics USA sales representative, or via dbmcorpusa.com. Due to the sterile nature of our medical devices, all sales are final – no refunds are offered, and eligible orders may be exchanged only, at DBM Aesthetic’s discretion, within 14 business days of delivery.

 

To be eligible for exchange, the Product must:

  • Be unopened and factory-sealed in original packaging
  • Include a verified lot number
  • Not be expired or nearing expiration
  • Have been stored under appropriate conditions
  • Be shipped back at the customer’s expense
Exchanges due to a shipping error, damaged shipment, or confirmed manufacturer defect will be replaced at no charge. All other returned Products are subject to inspection and may incur a restocking fee. To request an exchange, please complete the form on our Shipping & Exchange page.

 

Shipping Policy

All orders are shipped Monday – Friday. Orders received after 2PM PST will be shipped on the next business day. *Subject to change

Choice Shipping Address

×

You have no shipping addressesś.